Search

Search papers and lessons

Beer-Lambert Law

Level 2 · 10 min read

Beer-Lambert law: a solution weakens light exponentially with its concentration and path length, so the measurable absorbance is proportional to concentration.

On this page

  • Colour = topic mix
  • Discrete math
  • Inorganic chemistry
  • Analytical chemistry
  • Physical chemistry
  • Electromagnetism
  • Calculus
  • ReadReady to readNot yet

TL;DR

Light that passes through a coloured Solution gets dimmer, and the dimming depends on how much of the absorbing substance the beam meets. The Beer-Lambert law says that the light falls off exponentially with the concentration of the substance and with the distance the light travels through it. A quantity called absorbance, which is easy to measure, is therefore proportional to concentration, so a chemist can find an unknown concentration by measuring how much light is blocked.

Builds on: Logarithm, Molar Concentration · Leads to: Dust Extinction

Where it's used

Measuring concentration in a teaching or quality lab. A student wants to know how strong a food dye is in a drink. She makes a few standard solutions of known concentration, measures the absorbance of each in a spectrophotometer, and draws a straight line of absorbance against concentration. The unknown drink is then read off that line. The law is what makes the line straight.

Water monitoring. Environmental laboratories test water samples for nitrate and phosphate by adding a reagent that turns the sample coloured in proportion to the nitrate or phosphate present. The colour is then read as an absorbance, and the Beer-Lambert law converts that absorbance into a concentration, as long as the sample is not too dark.

Astronomy. Starlight is dimmed by interstellar dust on its way to Earth. Astronomers describe that dimming with a law of the same mathematical form, which is why Dust Extinction is taught as a close relative of this lesson.

How it works

Take one tiny instance: a solution in a cell whose light path is 1 cm long. The solution has a molar absorptivity of 1000 (the strength with which this substance absorbs, in litres per mole per centimetre), and a concentration of 0.001 mol/L. A beam of light goes in with intensity I0=100I_0 = 100 units. Trace what comes out.

  1. Find the absorbance. Multiply the three numbers: absorptivity times path length times concentration. That is 1000×1×0.001=11000 \times 1 \times 0.001 = 1. Check: the product is a pure number, with the units cancelling to nothing.
  2. Turn absorbance into transmitted light. Each unit of absorbance cuts the light by a factor of ten. So the transmitted fraction is 10−1=0.110^{-1} = 0.1. Check: a fraction of 0.1 means one tenth of the light gets through.
  3. Read off the output. The light that leaves is I=0.1×100=10I = 0.1 \times 100 = 10 units. Check: II is smaller than I0I_0, as it must be for an absorbing solution.
  4. Double the concentration. Now c=0.002c = 0.002 mol/L. The absorbance doubles to A=2A = 2, the transmitted fraction falls to 10−2=0.0110^{-2} = 0.01, and the output drops to 1 unit. Check: doubling the substance did not halve the light; it cut the remaining light by a factor of ten again. The effect is exponential, not linear.
  5. Output. Absorbance grows in a straight line with concentration, while the transmitted light falls off as a curve. The plot below shows both for a solution with absorptivity 8000 in a 1 cm cell.
00.000050.00010.000150.000200.20.40.60.81concentration (mol/L)transmitted fraction
  • transmitted fraction T
With a 1 cm path and absorptivity 8000, the transmitted fraction falls off as a curve. At 0.00005 mol/L the light is reduced to about 40 per cent.
flowchart LR
  A[Light in, I0] -- passes through path length l --> B[Solution absorbs a fixed fraction, set by the product of absorptivity, length and concentration] -- out --> C[Light out, I]

The math

Write I0I_0 for the light entering the sample, II for the light leaving it, ll for the path length in centimetres, cc for the molar concentration in mol/L, and ε\varepsilon (epsilon) for the molar absorptivity in L mol−1^{-1} cm−1^{-1}, a number that depends on the substance and the colour of the light.

Definition: Beer-Lambert law

For monochromatic light passing through a solution,

A=log⁡10(I0I)=ε l c,T=II0=10−A,A = \log_{10}\left(\frac{I_0}{I}\right) = \varepsilon\, l\, c, \qquad T = \frac{I}{I_0} = 10^{-A},

where AA is the absorbance (a pure number, with no unit), and TT is the transmittance, the fraction of light that gets through.

Step 1 in symbols: the light falls off by a fixed fraction per slice

Split the sample into thin slices of thickness dxdx. In each slice the light loses the same fraction of whatever it has, so the change in intensity is dI=−αI dxdI = -\alpha I\, dx, where α\alpha is a constant for the solution. This is the rule that makes the whole law work. It is an Ordinary Differential Equation whose solution is I(x)=I0e−αxI(x) = I_0 e^{-\alpha x}, the Exponential Function at work.

Step 2 in symbols: from the base e to the base 10

Over the full path, I=I0e−αlI = I_0 e^{-\alpha l}. Experiments are usually reported in base 10, so write α=εcln⁡10\alpha = \varepsilon c \ln 10. Since ln⁡10≈2.303\ln 10 \approx 2.303, this gives I=I0e−2.303 εcl=I0⋅10−εclI = I_0 e^{-2.303\,\varepsilon c l} = I_0 \cdot 10^{-\varepsilon c l}, because eyln⁡10=10ye^{y \ln 10} = 10^{y}. Check with step 1's numbers: 10−1=0.110^{-1} = 0.1, the same transmitted fraction as before.

Step 3 in symbols: absorbance is a logarithm

Divide both sides by I0I_0 and take log⁡10\log_{10} of the reciprocal. The logarithm of 10−y10^{-y} is −y-y, so A=log⁡10(I0/I)=εclA = \log_{10}(I_0/I) = \varepsilon c l. The absorbance is a straight line in cc for a fixed ll and ε\varepsilon. The second plot shows that line.

00.000050.00010.000150.000200.511.5concentration (mol/L)absorbance A
  • absorbance A = 8000 c
The same solution as the first plot. Absorbance is a straight line through zero, and at 0.00005 mol/L it is 0.40.

Step 4 in symbols: absorbances add when cells are stacked

Put two identical cells in a row. The first leaves I1=I0⋅10−A1I_1 = I_0 \cdot 10^{-A_1}, and the second takes that and leaves I2=I1⋅10−A2I_2 = I_1 \cdot 10^{-A_2}. So I2=I0⋅10−(A1+A2)I_2 = I_0 \cdot 10^{-(A_1 + A_2)}, and the total absorbance is the sum. This is why the path length ll enters the law as a product with cc: doubling the path is the same as doubling the concentration.

Worked examples

Example
Example 1: one cell, round numbers

A cell has path length l=1l = 1 cm. The solution has ε=1000\varepsilon = 1000 L mol−1^{-1} cm−1^{-1} and c=0.001c = 0.001 mol/L. The incoming light is I0=100I_0 = 100 units.

  1. Compute the absorbance: A=1000×1×0.001=1A = 1000 \times 1 \times 0.001 = 1.
  2. Compute the transmitted fraction: T=10−1=0.1T = 10^{-1} = 0.1.
  3. Compute the output: I=0.1×100=10I = 0.1 \times 100 = 10 units.

Interpretation: a solution of absorbance 1 lets one tenth of the light through.

Example
Example 2: the standard case

A cell has l=1l = 1 cm, ε=8000\varepsilon = 8000, and c=0.00005c = 0.00005 mol/L (that is 50 micromolar).

  1. Compute the absorbance: A=8000×1×0.00005=0.40A = 8000 \times 1 \times 0.00005 = 0.40. Check: 8000×0.00005=0.48000 \times 0.00005 = 0.4.
  2. Compute the transmitted fraction: T=10−0.40T = 10^{-0.40}. Using 10−0.4≈0.39810^{-0.4} \approx 0.398, about 40 per cent of the light gets through.
  3. Check against the plot: the curve at c=0.00005c = 0.00005 mol/L sits at about 0.40, and the line sits at 0.40 on the absorbance axis. The two views agree.

Interpretation: the absorbance is the number a spectrophotometer reports, and the transmittance is what it measures directly.

Example
Example 3: reading a concentration from a measurement

A student measures a made-up dye with ε=15000\varepsilon = 15000 L mol−1^{-1} cm−1^{-1} in a 1.00 cm cell and reads an absorbance of A=0.30A = 0.30. She wants the concentration.

  1. Rearrange the law: c=A/(εl)c = A / (\varepsilon l).
  2. Compute the denominator: εl=15000×1.00=15000\varepsilon l = 15000 \times 1.00 = 15000 L/mol.
  3. Divide: c=0.30/15000=0.00002c = 0.30 / 15000 = 0.00002 mol/L, which is 20 micromolar. Check: 15000×0.00002=0.3015000 \times 0.00002 = 0.30.
  4. Compute the transmitted fraction for the same measurement: T=10−0.30≈0.50T = 10^{-0.30} \approx 0.50, so half the light gets through.

Interpretation: the sample holds 20 micromolar of dye. A second sample with absorbance 0.60 would hold 40 micromolar, since absorbance is proportional to concentration.

Try it: a 0.50 cm cell with ε=12000\varepsilon = 12000 shows A=0.60A = 0.60. Find cc and then TT. Answer: c=0.60/(12000×0.50)=0.60/6000=0.0001c = 0.60 / (12000 \times 0.50) = 0.60 / 6000 = 0.0001 mol/L, which is 100 micromolar. Check: 12000×0.5×0.0001=0.612000 \times 0.5 \times 0.0001 = 0.6. Then T=10−0.60≈0.25T = 10^{-0.60} \approx 0.25, so about a quarter of the light gets through.

Common mistakes and tradeoffs

It is tempting to think that doubling the concentration halves the light; in fact the light falls by a factor of ten for each unit of absorbance, because the law is exponential. Doubling the concentration of a solution of absorbance 1 takes the transmitted fraction from 0.1 to 0.01, not to 0.05. Always convert absorbance to TT with 10−A10^{-A}, not by subtraction.

It is tempting to think that absorbance is a fraction of light; in fact it is a Logarithm of a ratio, so it has no unit and can exceed 1. An absorbance of 2 is a valid reading, and it means only 1 per cent of the light got through.

It is tempting to think the law holds at any concentration; in fact it fails when the solution is too dark. At high concentration molecules start to interact with each other, the molar absorptivity changes, and the straight line bends. Many instruments are reliable only up to an absorbance of about 1 to 2, and the usual remedy is to dilute the sample.

It is tempting to think any light colour can be used; in fact the law is for monochromatic light. Absorptivity depends on wavelength, because a molecule takes up only light whose energy matches its energy levels, so a broad beam gives a curve that does not follow the straight line. Measurements are taken at the wavelength where the substance absorbs most strongly, which also gives the most sensitive reading.

When to use it: a dilute, uniform solution, measured at one wavelength, with a known path length. When not to: scattering or cloudy samples, where light is lost without being absorbed; strongly concentrated solutions; and solids or rough surfaces. Alternatives include calibration curves built from standards without relying on the absolute value of ε\varepsilon, and fluorescence methods for very small amounts.

History

In 1729 Pierre Bouguer described how light weakens as it passes through more and more of a material. In 1760 Johann Heinrich Lambert put the idea in mathematical form, and the layers-of-equal-fraction picture used here comes from that tradition. In 1852 August Beer noted that the same loss depends on the amount of dissolved substance, and the two results were later combined into the single name used today. The law caught on because spectrophotometers made the measurement quick, and because it turns an invisible property of a solution into a single number on a dial.

Recap

  • Light passing through a solution loses a fixed fraction for each slice of path, which gives an exponential fall with path length and concentration.
  • Absorbance A=log⁡10(I0/I)A = \log_{10}(I_0/I) is the logarithm of the ratio, and it is proportional to εlc\varepsilon l c.
  • Transmittance is T=10−AT = 10^{-A}, so each unit of absorbance cuts the light by ten.
  • Absorbances add when cells are stacked, and the straight-line form lets a chemist read an unknown concentration from a measurement.

Read next: Dust Extinction, which applies the same form to starlight dimmed by interstellar dust.

Check yourself

QuestionWhat is the absorbance of a solution with ε=2000\varepsilon = 2000, l=1l = 1 cm and c=0.0002c = 0.0002 mol/L?Show answer

A=εlc=2000×1×0.0002=0.40A = \varepsilon l c = 2000 \times 1 \times 0.0002 = 0.40. Check: 2000×0.0002=0.42000 \times 0.0002 = 0.4.

QuestionA solution has absorbance 0.5. What fraction of the light is transmitted?Show answer

T=10−A=10−0.5≈0.316T = 10^{-A} = 10^{-0.5} \approx 0.316, so about 32 per cent of the light gets through.

QuestionWhy does the law use a logarithm, and what does it buy the measurer?Show answer

Light falls off exponentially, so the intensity ratio is not a linear quantity. Taking log⁡10\log_{10} of the reciprocal ratio turns the exponential into the straight line A=εlcA = \varepsilon l c. The measurer can then read concentration from absorbance by a simple proportion, and absorbances from separate cells add up.

QuestionA 2.00 cm cell with ε=500\varepsilon = 500 gives A=0.80A = 0.80. Find the concentration, then explain what would happen to the absorbance if the same solution were measured in a 1.00 cm cell.Show answer

c=A/(εl)=0.80/(500×2.00)=0.80/1000=0.0008c = A / (\varepsilon l) = 0.80 / (500 \times 2.00) = 0.80 / 1000 = 0.0008 mol/L. In a 1.00 cm cell the absorbance would halve to 0.40, because absorbance is proportional to path length as well as concentration.

Sources